Constraint PEAKMCUR_CALC_10HP_2


Slots on this instance:

Instance-Of: Constraint
Constraint-On: Elevator
Constraint.Expression:
'(=> (And (> (Motor_Torque_Releveling ?X) 40)
          (And (=< (Motor_Torque_Releveling ?X) 62.5)
               (= (Model-Id (Elevator.Motor ?X)) Motor_Model_M01)))
     (= (Motor_Peak_Current_Required ?X)
        (- (* 1.333 (Motor_Torque_Releveling ?X)) 3.333)))


Notes: